跳转到主要内容

上线前 主体注册推进中 · 欢迎提前发起 RFQ

工程数据、商务条款与规格矩阵今日即按生产级标准呈现。真实证书编号、已签 CTT 授权书及具名项目参考会在首个合格 RFQ 阶段经 NDA 释放。注册进度时间线见 /about。 ·

CTTCTT Cable Partner Desk
询价

Power Cable

YJV / YJV22 SNI Medium Voltage Power Cable

Project-grade medium voltage cable for Indonesian and overseas infrastructure tenders where standard coverage must be checked before quote.

Visualized as a construction stack, then translated into quote-ready fields. No fixed price, no checkout, no overclaiming certificate scope.

CTT product source
YJV22 armored cable 3D engineering model preview

Product model

YJV22 armored cable

Modeled from CTT public product-family references; exact size by datasheet.

Model: YJV22 0.6/1 kVMV model: YJV22 6/10kV 3 core

Construction

Voltage
6 kV to 30 kV
Conductor
Copper or aluminum
Insulation
XLPE
Sheath
PVC or PE
Armor
SWA, STA, or unarmored
Standards
SNI IEC 60502-2:2009, IEC 60502-2

RFQ checklist

Quotation requires voltage grade, conductor size, armor, sheath color, drum length, and test document requirements.

XLPE insulated core

Conductor shield / insulation shield verification

Armored or unarmored builds

Factory test report on request

Product visual basis

YJV / YJV22 SNI Medium Voltage Power Cable 3D model projection

Source-to-model evidence

Copper conductor, XLPE insulation, steel tape armor, PVC sheath for mechanical-risk routes.

CTT YJV22 line: 0.6/1 kV, copper conductor, XLPE insulation, steel tape armor, PVC sheath, 1 to 5 core options, GB/T 12706.1 and IEC 60502-1 signals, black sheath, drum package rows, buried-not-duct route wording, sealed cable-end protection, protruding end less than 300 mm public cue, package-label fields, upright drum handling, no-drop/no-flat-lay transport rules, and dry storage cues. The CTT 10kV source route adds YJV22 6/10kV 3-core, 6/10 kV rated-voltage, GB/T 12706.1-2008 / IEC60502-1 public-page signals, and a medium-voltage 6/10 kV layer witness panel for conductor shield / insulation shield / copper tape shield verification before quote. Indexed marketplace SKU signals add ZC-YJV22 2-core and 5-core armored ordering cues for local model calibration only.

Physical form kept

YJV / YJV22 power-cable anatomy from the 6/10 kV source route: long black sheath, XLPE insulation, steel-tape armor, screen-layer witness panel, and copper conductor face.

Storefront noise stripped

No domestic marketplace labels, retail decoration graphics, price stickers, or unverified SNI wording.

Visual status

Reference visual mapped to YJV22 armored cable. Exact dimensions, marking, and certification scope are verified against the manufacturer datasheet at quote.

Production visual gate

Final production visual should be rebuilt from verified product photos, selected MV screen/shield stack, datasheet dimensions, or CAD references.

Buyer-facing use

Use the model to understand cable form, construction logic, packaging cue, and RFQ fields before price discussion.

Claim boundary

The visual is not proof of final dimensions, certificate scope, or shipment packaging until the selected order is verified.

Upgrade route

Construction details below are mapped to manufacturer public-page references; selected-order parameters and certificate scope are confirmed by factory datasheet before quote.

Public spec cues shown in the visual

Voltage

0.6/1 kV

Confirm selected voltage class

MV route

YJV22 6/10 kV source route

Confirm selected MV datasheet before quote

Armor

Steel tape armored construction

Confirm armor layer and route condition

Structure

Copper conductor / XLPE insulation / PVC sheath

Confirm selected SKU by datasheet

Order cue

Model / spec / length / package / delivery site

Use RFQ schedule before quote

Route cue

Buried-route public wording

Confirm local installation rule before quote

Datasheet anchors behind the 3D

These are public CTT product-page signals used to keep the model tied to real cable construction. They are RFQ anchors, not final order values.

Model

YJV22 0.6/1 kV

CTT YJV22 product page

MV model

YJV22 6/10kV 3 core

CTT 10kV page route; verify selected datasheet

MV standard cue

GB/T 12706.1-2008 / IEC60502-1 public signal

Public page signal; standard edition and market rule need project check

MV screen prompt

conductor shield / insulation shield / copper tape shield

Layer witness panel is a verification prompt, not a fixed all-SKU claim

Structure

Copper conductor / XLPE insulation / steel tape armor / PVC sheath

Verify selected SKU by datasheet

Core family

1, 2, 3, 3+1, 4, 3+2, 4+1, 5

Select exact core count in RFQ

Route wording

Suitable for buried laying; not for duct laying in public page wording

Verify local installation rule before quote

Example row

2x4 mm2 approx. OD 13.5 mm; bend radius 189 mm

Public table example, not universal value

Example row

3x25 mm2 approx. OD 24.2 mm; bend radius 363 mm

Public table example, not universal value

Example row

4+1 25/16 mm2 approx. OD 28.1 mm; bend radius 393 mm

Public table example, not universal value

Example row

5x120 mm2 approx. OD 53.1 mm; bend radius 743 mm

Public table example, not universal value

Package

Black sheath; disk/drum package table rows

Confirm export packaging and drum length

Package label

Model / spec / voltage / length / weight / date / standard / rotation direction

CTT public packaging rule; verify final batch label

End protection

Sealed cable end; protruding end less than 300 mm public cue

Verify actual export packing before shipment

Handling

Sealed end, upright drum, no flat lay, no drop, dry storage

CTT public transport/storage rule; verify export method

Applications

Industrial parks

Mining power distribution

Utility substations

Data centers

Certificate signals

SNI IEC 60502-2:2009

Indonesia

Verify before order

Medium-voltage scope is useful for projects, but exact construction and test reports remain required.

Source / verify

Manufacturer authorization

Global

Verify before order

The prototype reserves a verification area. Final public wording must match the signed manufacturer letter.

Source / verify

Downloads

Medium voltage SNI cable datasheet

Reserved for a verified PDF asset.

Public SNI display source index

Links to public source index.

Build selector

Show buyers the cable construction logic before the RFQ.

Interactive build logic

Choose the cable story before quote

For 100 m coil inquiries, color schedules, building wiring, and distributor replenishment RFQs.

Send this build as RFQ
BV / BVR color coils 3D engineering model preview

Product model

BV / BVR color coils

Modeled from CTT public product-family references; exact size by datasheet.

Model family: ZR-BV / ZR-BVR / ZR-BVVB / ZR-RV / ZR-RVVStandard set: GB/T5023 / JB/T8734 / IEC60332-3

3D model basis

Uses the BV/BVR color-coil GLB with red 1x2.5 100 m sample cue and copper-end detail.

Voltage
450/750 V
Standard
IEC 60332-3 / project datasheet
Conductor
Copper, single-core BVR/BV family
Armor / sheath
None | PVC insulation
RFQ 草稿 — 欢迎提前沟通。本表单在您的设备本地撰写 WhatsApp 或邮件草稿 — 在您点击消息应用的发送按钮之前,没有任何内容会传出。PI、合同与银行账户在主体注册完成后开具(时间线见 /about);工程与商务沟通现在即可开始。

撰写 RFQ 草稿

下方字段在本地组合 WhatsApp 或邮件草稿 —— 在您点击目标应用的发送按钮之前,任何内容都不会离开您的设备。最终定价、交货期与付款条件以已签 PI 为准。

已从 产品上下文 加载 RFQ 上下文。请在发送前调整规格、数量、路线与文件需求。

最终报价必须在任何交易前确认制造商收款方、准确型号、证书范围、工厂测试报告、包装与出货文件。

必需同意项